Tag: NVMe

  • Checking NVMe Disk

    Checking NVMe Disk

    You can use nvme-cli to check your NVMe disks. To install nvme-cli, run

    On Ubuntu/Debian

    sudo apt-get install -y nvme-cli
    

    On RHEL

    sudo yum install nvme-cli
    

    To list of NVMe drives, use

    nvme list
    

    Example

    [root@server52 ~]# nvme list
    Node             SN                   Model                                    Namespace Usage                      Format           FW Rev  
    ---------------- -------------------- ---------------------------------------- --------- -------------------------- ---------------- --------
    /dev/nvme0n1     S439NA0N900171       SAMSUNG MZQLB1T9HAJR-00007               1         531.97  GB /   1.92  TB    512   B +  0 B   EDA5402Q
    /dev/nvme1n1     S439NA0N900057       SAMSUNG MZQLB1T9HAJR-00007               1         532.00  GB /   1.92  TB    512   B +  0 B   EDA5402Q
    [root@server52 ~]# 
    

    To find smart data, run

    nvme smart-log DEVICE_NAME_HERE
    

    Example

    [root@server52 ~]# nvme smart-log /dev/nvme0n1
    Smart Log for NVME device:nvme0n1 namespace-id:ffffffff
    critical_warning                    : 0
    temperature                         : 39 C
    available_spare                     : 100%
    available_spare_threshold           : 10%
    percentage_used                     : 0%
    data_units_read                     : 130,334,241
    data_units_written                  : 69,361,921
    host_read_commands                  : 866,547,209
    host_write_commands                 : 710,448,251
    controller_busy_time                : 998
    power_cycles                        : 88
    power_on_hours                      : 5,464
    unsafe_shutdowns                    : 83
    media_errors                        : 0
    num_err_log_entries                 : 0
    Warning Temperature Time            : 0
    Critical Composite Temperature Time : 0
    Temperature Sensor 1                : 39 C
    Temperature Sensor 2                : 43 C
    Temperature Sensor 3                : 47 C
    Thermal Management T1 Trans Count   : 0
    Thermal Management T2 Trans Count   : 0
    Thermal Management T1 Total Time    : 0
    Thermal Management T2 Total Time    : 0
    [root@server52 ~]# 
    

    To see the NVMe error log

    nvme error-log	DEVICE_NAME_HERE